Shopping Cart

No products in the cart.

Acel logo

Aecl AVC-310 Series CO2, Temperature & Humidity Transmitter (RS485 or 4~20mA) Controller

SGD460.00 inc. TAX
SGD422.02 exc. TAX

In stock

Aecl
CO2 Transmitter

CO2, Temperature & Humidity Transmitter
and CO2 Controller with Relay output
(AVC-310 Series)

Made in Taiwan

AVC-310 series CO2 transmitter is designed for measuring the ambient carbon dioxide concentration or with optional measurement of temperature & humidity and provide signal output for monitoring or control. Utilizing NDIR sensing element ensures its accuracy of measurement. By controlling the ventilation or air-conditioning system based on actual demand, it helps to reduce energy consumption while maintaining a healthy indoor climate.

Features:

  • Rapid response time, high stability, high accuracy
  • Internal sensing element design
  • Streamline shape and elegant design
  • Complete product line and multifunction for various applications

Specifications:

Model No. AVC-301 CO2 transmitter

  • Measurement range: 0~2,000 ppm (Standard) or 0~9999 ppm (High level)
  • Sensing element: Gold-plated infrared (NDIR) wave-guide technology with Automatic Baseline Correction (ABC) and passive gas diffusion (no moving parts)
  • Response time: < 10 sec. @ 30 cc/min. flow rate ; < 3 min. diffusion time
  • Accuracy (at 25℃): 0~2000ppm(± 30ppm ±3% of reading), 2001~9999ppm(± 70ppm ±3% of reading)
  • Repeatability: ± 20ppm + (±reading * 1%)
  • Zero Drift: < ± 10ppm/yr. with Automatic Baseline Correction (ABC)
  • Signal output: DC 4~20mA; DC 0~10 V; RS485 (Modbus RTU)

Model No. AVC-311 CO2 + temperature & humidity transmitter

  • Measurement range:
    • CO2: 0~2,000 ppm (Standard) or 0~9999 ppm (High level)
    • Temperature: -10 ~ +50℃
    • Humidity: 0 ~ 100 %RH
  • Sensing element:
    • CO2:Gold-plated infrared (NDIR) wave-guide technology with Automatic Baseline Correction (ABC) and passive gas diffusion (no moving parts)
    • Temperature & humidity: CMOS sensor
  • Respone time:
    • CO2: <10 sec. @ 30cc/min. flow rate ; <3 min. diffusion time
    • Temperature: min. 3 sec.;max. 30sec. at τ63%
    • Humidity: < 8 sec. at τ63%
  • Accuracy (at 25℃):
    • CO2: 0~2000ppm(± 30ppm ±3% of reading), 2001~9999ppm(± 70ppm ±3% of reading)
    • Temperature: ±0.3℃
    • Humidity: ±2 %RH
  • Repeatability:
    • CO2: ±20ppm + (±reading * 1%)
    • Temperature: ±0.1℃
    • Humidity: ±0.1 %RH
  • Zero Drift:
    • CO2: < ± 10ppm/yr. with Automatic Baseline Correction (ABC)
    • Temperature: < 0.04 ℃/yr
    • Humidity: < 0.5 %RH/yr
  • Signal output: RS485 (Modbus RTU)

General Specifications:

  • Display range:
    • CO2: 0 ~ 2000 ppm (Standard); 0 ~ 9999 ppm (High level);
    • Temp.: -9.99 ~ 50.00℃ ; Humidity: 0 ~ 99.9 %RH
  • Alarm output: Relay output N.O, N.C ( 2A / 30V DC)
  • Pressure dependence: CO2: 1.6% reading per kPa
  • Environmental:
    • Temperature: -10 ~ +50℃
    • Humidity: 0 ~ 95%RH (without condensation)
  • Storage temperature: -20 ~ +70 ℃.
  • Warm-up time: ≤ 1 min. (at full specs ≤ 15 minutes)
  • Power Supply: 12~36 VDC, AC 24V (50/60hz)
  • Power consumption: <1.7W (peak value)
  • Installation: Wall mount; Duct-mount
  • Dimensions(mm)
    • Wall-mount: 113.57(H) x 80(W) x 28.79(D)
    • Duct-mount: 142.4H x 85W x 47.2D; sensing probe: 130
  • Case material: Fireproof ABS
  • IP rating:
    • Wall-mount: IP30
    • Duct-mount: IP65
  • Certifications: CE and FCC

Standard Package:

  • CO2 Transmitter
  • User Manual

*All information is subject to change without prior notice.