Kaiterra logo

Kaiterra SE200AW/PW Sensedge Mini for WELL 9-in-1 PM2.5 PM10 TVOC CO2 NO2 CO O3 Temperature Humidity

Contact Us for Official Quote

Kaiterra IAQ Monitoring System
Kaiterra Sensedge Mini for WELL

Smart Air Quality Monitoring Solutions
Commercial Grade Sensors 
(Model No.: SE-200AW/PW)

Products of Switzerland

Descriptions

Kaiterra creates high-accuracy indoor air quality monitoring system and data solutions for consumers, businesses, governments, and industrial use.

The Sensedge Mini for WELL provides real-time, accurate measurements of PM2.5, PM10, TVOC, CO2, NO2, CO and O3 concentrations, as well as temperature and relative humidity readings. Made for WELL projects to earn 9 points and replace performance testing for Air & Thermal Comfort. With multiple power, connectivity, and installation options, the Sensedge Mini is made to the satisfaction of building owners, facility managers, tenants, and employees.

Kaiterra IAQ monitoring system is tested and certified by the RESET standard for accuracy, the Sensedge Mini is fully compliant with various green building and air quality standards, including Works with WELL, LEED, RESET, the Living Building Challenge, and Fitwel.


Kaiterra Sensedge Mini Demo: Everything you need to know

Designed to Make a Difference

    • Best-in-Class Sensors & Algorithms
      The accuracy and reliability of your data is ensured by sensing components made in Switzerland, and the innovative cloud-based calibration used in our products.
    • Modular Design
      Kaiterra’s signature modular design allows customizable modules to fit specific monitoring requirements, and completely removes the need for the traditional costly calibration processes.
    • Secure & Accessible Data
      Your data is brought to life by the Kaiterra Dashboard and Live Air app, where you can view real-time and historical data, identify air pollution trends, set up alerts, and download for further analysis.
    • Robust Quality Control
      Our 100% traceable production process, along with top-tier, Apple MFi certified factories that we partner with is an additional step we take to ensure that our products are of the highest calibre.


Learn more about Kaiterra’s signature modular design

Applications

  • Online real-time detecting indoor air quality
  • Green Building Assessment
  • BAS and HVAC systems
  • Smart Workplace System
  • Fresh Air Controlling System
  • Building Energy Saving Reconstruction and Assessment System
  • Classroom, office, exhibition hall, shopping mall, any public places

Features

  • RESET Grade B Certified
  • Works with WELL
  • Modular Design
  • Cloud & 1-hour Local Storage
  • Minimal Unobtrusive Design
  • Kaiterra Data Cloud Platform


Kaiterra Data Platform Demo: Unlock the power of your IAQ data

Specification:

  • Particulate Matter Sensor (KM-201)
    • Sensor technology: Laser particle sensor (Light scattering)
    • Mass concentration range: 0 to 1,000μg/㎥
    • Mass concentration size:
      • PM2.5: 0.3 to 2.5 μg/m3
      • PM10.0: 0.3 to 10.0 μm
    • Mass concentration accuracy for PM2.5
      • 0 to 30 μg/m3:  ±3 μg/m3
      • 30 to 1000 μg/m3:  ±10% m.v.
    • Mass concentration accuracy for PM10
      • 0 to 30 μg/m3:  ±3 μg/m3
      • 30 to 1000 μg/m3:  ±15% m.v.
    • Sensor output resolution: 1 μg/m3
    • Calibration: Calibrated against standardized aerosol mix
    • WELL specification requirements:
      • Adjustable particle density (K-factor) to accommodate project/region specific particulate profile.
      • Complies with WELL Performance Verification Guidebook to be used in WELL certification.
  • TVOC Sensor (KM-201)
    • Sensor technology: Mulit-pixel metal oxide sensor (MOx)
    • Target gas profile: Complex mixture of 22 VOCs1 as defined by Molhave et al.
    • Measuring Range: 0~1,382 ppb ; 0~5,482 ug/m³
    • Accuracy: ±15% ±4 ppb ; ±15 % ±18 ug/m³
    • Sensor output resolution: 1 ug/m³
    • Calibration: Calibrated again ethanol
    • Sampling process: Passive
    • WELL specification requirements:
      • Calibration gas: ethanol
      • Target gas profile (ppb=µg/m³ conversion factor under STP): 22 VOC mixed per Molhav et al. (1 ppb = 4.57 µg/m³)
      • Complies with WELL Performance Verification Guidebook to be used in WELL certification.
  • Ozone Sensor (KM-208)
    • Sensor technology: Electrochemical
    • Measurement range: 0 to 2,000 ppb
    • Accuracy: 0 to 100ppb: ±10ppb ; >100ppb: ±10%
    • Typical response time: <90s
    • Sensor output resolution: 1 ppb
    • Target gas: O3
    • Interference gas: CL2*⁵
  • Carbon Dioxide CO2 Sensor (Built-in)
    • Sensor technology: Non-Dispersive Infrared (NDIR)
    • Measurement Range:
      • 400 ~ 5000ppm2
      • Up to 10,000 ppm extended range3
    • Accuracy: ± 40 ppm ± 3%⁴ (Comply with ANSI/ASHRAE Standard 62.1-2022)
    • Sensor output resolution: 1 ppm
    • Target gas: CO2
  • NO2 Sensor (KM-208)
    • Sensor Technology: Electrochemical
    • Measurement Range: 0 to 2,000 ppb
    • Accuracy: 0 to 100 ppb: ±10 ppb ; >100 ppb: ±10 %
    • Sensor output resolution: 1 ppb
    • Target gas: NO2
    • Interference gas: CL2⁶
  • CO Sensor (KM-208)
    • Sensor Technology: Electrochemical
    • Measurement Range: 0 to 100 ppm
    • Accuracy: 0 to 20 ppm: ±1 ppm ; >20 ppm: ±5 %
    • Sensor output resolution: 0.1 ppm
    • Target gas: CO
  • Temperature Sensor (Built-in)
    • Sensor Technology: Digital sensor
    • Measuring Range: -40℃~125℃
    • Accuracy: Temperature︰±0.3℃, Comply with WELL⁷
    • Sensor output resolution: 0.01℃
  • Humidity Sensor (Built-in)
    • Sensor technology: Digital sensor
    • Measuring Range: 0~100%RH
    • Accuracy: ±3%RH
    • Sensor output resolution: 0.01% RH

Device Specification

  • Power
    • USB-C: 100 – 240 V AC: (5V 1.8A DC)
    • Direct Wiring: 12 – 30 V DC
    • PoE (Available for SE-200PW/P/PL): IEEE 802.3af (PoE), Class3
    • IEEE 802.3at (PoE+), Class3
    • PD maximum power ≤ 10 W
    • PSEs: Midspan & endspan supported Cable: Cat5 (Cat5e, Cat6, and Cat6a)
    • Power Consumption: Average: 1.7W
    • Peak: 4~5W
  • Data Logging & Storage
    • Frequency of readings (Log interval):
    • 1 minute, 1 hour, 1 day
    • Data push interval: 1 minute ⁸
    • Onboard memory: 1 hour of data
  • Connectivity 
    • Wi-Fi:
      2.4 GHz 802.11 b/g/n
      Security supported: 64/128 WEP, WPA-PSK, WPA2-PSK, WPA, WPA2 Personal Ethernet:
      IEEE 802.3
      Data rate: Up to 100 Mbps
  • Integration
    • BACnet/IP
    • RS-485 Modbus/RTU
    • Cloud MQTT
    • On premise MQTT
    • Open API
  • Installation
    • Methods: Surface mount, Drywall mount, Electrical box mount
  • Security
    • Kaiterra’s platform architecture meets the most stringent security standards and is regularly subjected to 3rd party penetration tests. Read more about our security here.
  • Certifications
    • Quality: RESET Grade B
    • Healthy Building: Works with WELL
    • Building Automation:
    • BTL: Certified under the BACnet Smart Sensor (B-SS) device profile
    • Environmental: ROHS, WEEE, REACH Safety: BIS (India), CE (Europe), FCC (US) , IC (Canada), MIC (Japan), RCM (Australia & New Zealand),
    • SRRC (China), TDRA (UAE)
  • Operating conditions
    • Operating temperature: 0 – 50 °C
    • Operating humidity: 5 to 95 %RH, non- condensing
  • Size & Weight
    • 155 mm x 129 mm x 34 mm (6.1” x 5.1” x 1.3”) 370 g (0.82 lbs)
  1. n-Hexane, n-Nonane, n-Decane, n-Undecane ,1-Octane, 1-Decene, Cyclohexane, m-Xylene, Ethylbenzene, 1,2,4-Trimethylbenzene, n- Propylbenzene, a-Pinene, n-Pentanal, n-Hexanal, Iso-propanol, n-Butanol, 2-Butanone, 3-Methyl-3-butanone, 4-Methyl-2-pentanone, n- Butylacetate, Ethoxyethylacetate, 1, 2-Dichloroethane
  2. Extended exposure to concentrations below 400 ppm may result in incorrect operation of ABC algorithm and should be avoided
  3. Sensor provides readings in the extended range but the accuracy may be lower than that specified in the table.
  4. The accuracy specification covers environments ranging from 0-50°C and 0-80% RH, and complies with indoor air quality standards ANSI/ASHRAE Standard 62.1-2022 at 25°C.
  5. Engineered to isolate NO₂ cross-interference for accurate O₃ measurement.
  6. Engineered to isolate O₃ cross-interference for accurate NO₂ measurement.
  7. As a RESET Certified Grade B air quality monitor, this device automatically meets technical requirements for this parameter.
  8. Customizable upon request
Weight2 kg

Kaiterra Sensedge Mini SE-200 Indoor Air Quality Monitor Data Sheet

Download(345 KB)
web statistics