Carbon Monoxide Detector / Transmitter
(Model No.: F2000TSM-CO-C101)
F2000TSM-CO-C101 is specifically designed to detect and transmit carbon monoxide level in the enclosed or semi-enclosed car parks and to regulate the environment of carbon monoxide. It is designed for easy installation and minimum maintenance during operation.
Product Features
- Wall mounting, real time detect CO level with measuring range of 0~100ppm
- Electrochemical sensor which offer several advantages over traditional electrochemical sensors
- With a long life, good long term stability, and high accuracy, the CO sensor is environmentally friendly without risk of electrolyte leakage
- With simple calibration
- The special design of easy sensor’s replacement makes customers replace sensor easily by themselves
- Full time CO level detection, even the slightest leak can be detected
- One analog output of the measurement of carbon monoxide concentration with 4~20mA
- Special built-in Self-Zero Correction algorithm
- Modbus RS-485 communication with 15KV antistatic protection, also can be calibrated carbon monoxide measurement via the interface
Typical Application
- Residential and commercial CO detectors and transmitters
- Centilation control for indoor parking garages
- Recreational vehicle CO detectors
- Kitchen rooms and restaurants
- Freezing machine rooms and other places where air quality is easy to worsen
Specification:
- CO Measurment
- Gas detected: Carbon Monoxide
- Sensing element: Battery operable electrochemical sensor
- Gas sample mode: Diffusion
- Warm up timeL 1 hour (first time)
- Response Time: Within 60 seconds
- Singal Update: 1s
- CO Measuring Range: 0 ~ 100ppm
- Accuracy: ±1ppm (at 20±5℃ / 50±20%RH)
- Stability: ±5% (over 900 days)
- Sensor life: Up to more than 5 years lifetime
- Electrical
- Power supply: 24VAC/24VDC
- Consumption: 1.5W
- Wiring connectionsL 5 terminal blocks (max.)
- Outputs
- Linear analog output: 1 x Analog output, 4~20mA
- D/A resolution: 16 bit
- D/A conversion accuracy: 0.1ppm
- Modbus RS485 Communicatio Interface: Mobus RS485 interface 9600/14400/19200(default), 28800 bps, 38400 bps (programmable selection), 15KV antistatic protection
- General Performanace
- Operation temperature: 0~60℃ (32~140℉)
- Operation humidity: 5~99%RH, non-condensing
- Storage conditions: 0~50℃ (32~122℉); 5~95%RH
- Net weight: 190g
- Dimension: 100mm x 80mm x 28mm
- Installation standard: 65mmx65mm or 2”x4” wire box
- Housing and IP class: PC/ABS fireproof plastic material, protection class: IP30
- Compliance: EMC Directive 89/336/EEC
Accessories
- Cardon Monoixide Detector/Transmitter
- User Manual