Categories
Category
Home > Products > Indoor IAQ / Outdoor Air Quality > Air Quality Transmitter / Controller > Aecl AQD-102 6-in-1 CO2 CO HCHO PM2.5 Humidity Temperature Air Quality Display (527 x 217)
Aecl AQD-102 6-in-1 CO2 CO HCHO PM2.5 Humidity Temperature Air Quality Display (527 x 217)
enlarge
  • NULL
  • NULL
  • NULL
  • NULL
  • NULL
  • NULL

Aecl AQD-102 6-in-1 CO2 CO HCHO PM2.5 Humidity Temperature Air Quality Display (527 x 217)


Rating: 0 out of 100 - based on 0 review(s) | Write Review | Add to Compare
Ask for Quote
Item details
SKU: ADQ-102

Stock: Out of stock

Brand: Aecl
  Share This   Add To Facebook

Aecl AQD Series
6-in-1 Air Quality Display
CO2, CO, HCHO, PM2.5, Humidity and Temperature
(Model No.: AQD-102)

Made in Taiwan

AQD series displays four most crucial parameters of IAQ; CO2 level, CO, HCHO, PM2.5 concentration, humidity and temperature. It also provides date, day and time. It uses good quality sensors; such as the NDIR CO2 sensor, laser scattering principle sensor for PM2.5, temperature and humidity sensors which are usually available only in laboratory air quality diagnostic equipment. AQD-102 series measures CO2, CO, HCHO, and PM2.5 concentration which may not be noticeable by us and used the reading to control ventilation so that the indoor CO2 level can be kept below the recommended ASHRAE limit of 1000ppm and it can ensure better indoor air quality. Monitoring humidity is very important as extended period in an area with humidity over 60% or below 40% can create conditions for mold and mildew growth that may cause
allergies and affect general health.

Features:

  • 6 indicators of air quality: CO2, CO, HCHO, PM2.5, Temperature, Humidity.
  • Clock and Calendar Display: Year, Month, Date, Day, Time.
  • Bulit-in Non-dispersive infrared (NDIR) CO2 sensor with automatic calibration
  • Built-in Laser Distributing PM2.5 sensors for reliable air detection
  • Built-in Built-in high accuracy and reliable Temperature, humidity sensors.
  • Clear and Bright 7 segment LED display
  • Non-stop real time data monitoring
  • 3 Relays can be used to activate ventilation system or alarm devices
  • RS485 Modbus communication or switchable RS485
  • Comply with " Taiwan indoor air quality management act"
  • Maintenance-free for normal indoor applications
  • CE & FCC Certification
  • Customized specification is avaialable upon request

Applications:
Indoor places where would be required to detect CO2, CO, HCHO, PM2.5, Temperature and Humidity such as,

  • Commercial building / office
  • Train station
  • Shopping Mall
  • Warehouse
  • Museum
  • Hospital
  • Medical Center
  • Factory
  • Library

Specifications:

  • Measurements: CO2, CO, HCHO, PM2.5, Humidity, Temperature
  • Clock and calendar: Real time clock and calendar, with battery backup
  • CO2 Measurement
    • Measurement principle: Non-dispersive infrared (NDIR) with automatic calibration
    • Range: 0 ~ 9999 ppm
    • Accuracy: 0 ~ 2000ppm ±3% and ±40 ppm*
    • Response time: 2 minutes by 90%
    • Maintenance: Maintenance-free for normal indoor applications
    • Display: digit 4 digits, 0 ~ 9999
    • Relay setting: 1200ppm
    • Hysteresis: 100ppm
  • CO Measurement
    • Measurement principle: Electro-chemical
    • Range: 0 ~ 100 ppm
    • Accuracy: ±5%
    • Repeatability: Reading ±2%
    • Response time: τ90 ≦ 30 sec.
    • Zero point drift: ≦5% / yr
    • Relay alarm setting: 9ppm (default)
    • Hysteresis: 2ppm
  • HCHO Measurement
    • Measurement principle: Electro-chemical
    • Range: 0 ~ 3 ppm
    • Accuracy: ±5%
    • Repeatability: <±0.05ppm
    • Response time: <120 sec. (HCHO: 1ppm)
    • Long-term drift: Over 2 years
    • Relay alarm setting: 0.08ppm (default)
    • Hysteresis: 0.02ppm
  • PM2.5 Measurement
    • Measurement principle Laser distributing
    • Range: 0~ 600 μg/m3
    • Accuracy: 0~ 100μg/m3(±10%μg/m3) , 100~ 600μg/m3 (±10%)
    • Response time: ≦10 s
    • Maintenance: Maintenance-free for normal indoor applications
    • Display: digit 3 digits, 0 ~ 999
    • Relay setting: 35 μg/m3
    • Hysteresis: 10 μg/m3
  • Humidity Measurement
    • Range: 0 ~ 95 %RH
    • Accuracy tolerance: ± 3 %RH (typical)
    • Repeatability: ± 0.1 %RH
    • Response time: < 8 s (τ63%, 25℃)
    • Long-term drift: < 0.5 %RH / year
    • Display: digit 2 digits, 0 ~ 99
    • Relay setting: 70%RH
    • Hysteresis: 5%RH
  • Temperature Measurement
    • Range : -10 ~ 50°C
    • Accuracy tolerance: ± 0.3 ℃ (typical)
    • Repeatability: ± 0.1 ℃
    • Response time: 5~30 s (τ63%, 25℃)
    • Long-term drift: < 0.04 ℃/ year
    • Display: digit 3 digits (One decimal point), 0.0 ~ 99.9
    • Relay setting: 28℃
    • Hysteresis: 1℃
  • Power Supply: 12 VDC (supply with an AC adapter 100 ~ 240V / 50 ~ 60Hz)
  • Current consumption: 1.2A (max)
  • Display: 7 segment LED display
  • Storage: Micro SD card 8G or 16G (Transcend, Adata and Kingston are recommended, not included in product kit)
  • Memory capacity: Depending on SD card capacity
  • Storage format: CSV
  • Installation: wall-mount
  • Output signals: RS485 (Modbus RTU)
  • Alarm output: 3 Relay outputs can be specified as CO2, CO, HCHO, PM2.5, relative humidity, or temperature N.O. and N.C. (2A/30VDC)
  • Housing material: PMMA panel (4mm), SPCC casing (1mm)
  • Dimensions (mm): 527 x 217 x 32
  • Weight: 2700g

*In normal IAQ applications. Accuracy is defined after minimum 3 weeks of continuous operation with ABC. However, some industrial applications do require maintenance ℃. Accuracy is specified at room temperature +25°C and at normal pressure 101.3 kPa. Specification is referenced to certified calibration mixtures. Uncertainty of calibration gas mixtures (±1% currently) is to be added to the specified accuracy for absolute measurements.

Standard Package:

  • 6-in-1 Air Quality Display
  • User Manaul

*All information is subject to change without prior notice.