Categories
Category
Home > Products > Indoor IAQ / Outdoor Air Quality > Air Quality Detecting System > Kaiterra Sensedge Mini (PoE version) 5-in-1 PM2.5 TVOC CO2 Temperature RH Monitoring Solutions
Kaiterra Sensedge Mini (PoE version) 5-in-1 PM2.5 TVOC CO2 Temperature RH Monitoring Solutions
enlarge

5 Sold

  • NULL
  • NULL
  • NULL
  • NULL
  • NULL
  • NULL
  • NULL
  • NULL
  • NULL
  • NULL
  • NULL
  • NULL
  • NULL
  • NULL
WorkswithWELL

Kaiterra Sensedge Mini (PoE version) 5-in-1 PM2.5 TVOC CO2 Temperature RH Monitoring Solutions


Rating: 0 out of 100 - based on 0 review(s) | Write Review | Add to Compare
Ask for Quote
Item details
SKU: SE-200P

Stock: Out of stock

Brand: Kaiterra
  Share This   Add To Facebook

Kaiterra Sensedge Mini
Smart Air Quality Monitoring Solutions
Commercial Grade Sensors 
(Model No.: SE-200P)

Products of Switzerland

Descriptions

Kaiterra creates high-accuracy air quality monitors and data solutions for consumers, businesses, governments, and industrial use.

The Sensedge Mini provides real-time, accurate measurements of PM2.5, TVOC, and CO2 concentrations, as well as temperature and relative humidity readings. With multiple power, connectivity, and installation options, the Sensedge Mini is made to the satisfaction of building owners, facility managers, tenants, and employees.

Tested and certified by the RESET standard for accuracy, the Sensedge is fully compliant with various green building and air quality standards, including WELL v2, LEED, RESET, the Living Building Challenge, and Fitwel.

Designed to Make a Difference

  • Best-in-Class Sensors & Algorithms
    The accuracy and reliability of your data is ensured by sensing components made in Switzerland, and the innovative cloud-based calibration used in our products.
  • Modular Design
    Kaiterra’s signature modular design allows customizable modules to fit specific monitoring requirements, and completely removes the need for the traditional costly calibration processes.
  • Secure & Accessible Data
    Your data is brought to life by the Kaiterra Dashboard and Live Air app, where you can view real-time and historical data, identify air pollution trends, set up alerts, and download for further analysis.
  • Robust Quality Control
    Our 100% traceable production process, along with top-tier, Apple MFi certified factories that we partner with is an additional step we take to ensure that our products are of the highest calibre.

Applications

  • Online real-time detecting indoor air quality
  • Green Building Assessment
  • BAS and HVAC systems
  • Smart Home System
  • Fresh Air Controlling System
  • Building Energy Saving Reconstruction and Assessment System
  • Classroom, office, exhibition hall, shopping mall, any public places

Features

  • RESET Grade B Certified
  • Works with WELL
  • Modular Design
  • Cloud & 1-hour Local Storage
  • Minimal Unobtrusive Design

Specification:

  • Particulate Matter Sensor (KM-200, Silver Module)
    • Mass concentration range: 0 to 1,000μg/㎥
    • Mass concentration size:
      • PM2.5: 0.3 to 2.5 μg/m3
      • PM10.0: 0.3 to 10.0 μm
    • Mass concentration accurcy for PM2.5
      • 0 to 30 μg/m3:  ±3 μg/m3
      • 30 to 1000 μg/m3:  ±10% m.v.
    • Sensor output resolution: 1 μg/m3
    • Sensor technology: Laser particle sensor (Light scattering) 
    • Typical response time: 10 s
    • Recommended lifetime: 
      • High pollution concentration (> 200 μg/m3): 1.3 years
      • Low pollution concentration (< 100 μg/m3): 2 years
    • Calibration: Calibratted against standized aerosol mix
  • TVOC Sensor (KM-200, Gold Module)
    • Target gas profile: Complex mixture of 22 VOCs1 as defined by Molhav et al.
    • Measuring Range: 0~60000 ppb
    • Accuracy: ±15% ±8 ppb
    • Sampling process: Diffusion
    • Calibration: Calibrated again ethanol
    • Sensor output resolution: 1 ppb
    • Sensor technology: Mulit-pixel metal oxide sensor (MOx)
    • Typical start-up time: 0.4 ms
  • 1 n-Hexane, n-Nonane, n-Decane, n-Undecane ,1-Octane, 1-Decene, Cyclohexane, m-Xylene, Ethylbenzene, 1,2,4-Trimethylbenzene, n-Propylbenzene, a-Pinene, n-Pentanal, n-Hexanal, Iso-propanol, n-Butanol, 2-Butanone, 3-Methyl-3-butanone, 4-Methyl-2-pentanone, n-Butylacetate, Ethoxyethylacetate, 1, 2-Dichloroethane.
  • Carbon Dioxide CO2 Sensor (Built-in)
    • Target gas: CO2
    • Measurement Range:
      • 400 ~ 2000ppm2
      • Up to 10,000 ppm extended range3
    • Accuracy4: ± 3% ±40 ppm
    • Typical response time: 2 minutes by 90%
    • Sensor technology: Non-Dispersive Infrared (NDIR)
    • Sensor output resolution: 1 ppm
    • Recommended lifteime: 15+ years
  • 2 Extended exposure to concentrations below 400 ppm may result in incorrect operation of ABC algorithm and should be avoided.
    3 Sensor provides readings in the extended range but the accuracy may be lower than that specified in the table.
    4 Accuracy is specified over operating temperature range. Specification is referenced to certified calibration mixtures. Uncertainty of calibration gas mixtures (±2% currently) is to be added to the specified accuracy for absolute measurements.
  • Temperature Sensor (Built-in)
    • Measuring Range: -20℃~100℃
    • Accuracy: Temperature︰±1℃
    • Long term drift5: <0.03 ℃/yr
    • Typical response time6: >2s
    • Sensor technology: Digital sensor
    • Sensor output resolution: 1℃
    • Recommended lifetime: 10 years
  • 5 Typical value for operation in normal RH/T operating range. Higher drift values may occur due to contaminant environments with vaporized solvents, out-gassing tapes, adhesives, packaging materials, etc.
    6 Temperature response times strongly depend on the type of heat exchange, the surrounding surface and the airflow in the final application environment.
  • Humidity Sensor (Built-in)
    • Measuring Range: 0~99%RH
    • Accuracy: ±5%RH
    • Long term drift: <0.25% RH/yr
    • Typical response time7: >8s
    • Sensor technology: Digital sensor
    • Sensor output resolution: 1% RH
    • Resolution: 1%RH
    • Recommended lifetime: 10 years
  • 7 Humidity response times strongly depend on the surrounding surface and the airflow in the final application environment.
  • General Data
    • Calibration: Calibration via hot-swappable sensor modules
    • Operating conditions:
      • Temperature: 0~50℃
      • Humidity︰5~95%RH, non-condensing
    • Data storage & logging:
      • Frequency of readings (Log interval): 1 minute, 1 hour, 1 day
      • Data push interval: 1 minute8
      • Onboard memory: 1 hour of data
    • Dimension: 155(L) x 129(W) x 34(H) mm (6.1 x 5.1 x 1.3 in.)
    • Weight: 370g (0.82 lbs)
    • Warranty & durability:
      • Standard warranty: 1 year9
      • Expected lifespan: 5 to 7 years
    • 8 Customizable upon request
      9 Optional extended warranty with contract
  • Power and Connectivity Options
    • InstallationL Surface, Drywall, Electrical box, or ceiling mount
    • Wi-Fi:
      • 2.4 GHz 802.11 b/g/n
      • Security supported: 64/128 WEP, WPA-PSK, WPA2-PSK, WPA, WPA2 Personal
    • Ethernet: IEEE 802.3; Data rate: Up to 100 Mbps
    • Modbus (RS-485): RS-485 Modbus/RTU
    • Integration: BACnet/IP; Local and cloud MQTT; Open API
    • Power:
      • 100~240V AC via USB Type-C
      • 12~30V DC via direct wiring
      • PoE (SKU:SE000200P):
        • IEEE 802.3af (PoE), Class3
        • IEEE 802.3at (PoE+), Class3
        • PD maximum power < 10 W
        • PSEs: Midspan & endspan supported
        • Cable: Cat5 (Cat5e, Cat6, and Cat6a)10
      • 10 Total length of cabling up to 100 meters. However, we don’t recommend using cables longer than 50m to guarantee the stability of power and data transmission