Mel-8704R AC/DC EMF, Temperature, & Flashlight in One Handheld instrument
Professional Instructment for Ghost Detection-Paranormal Activity
Fun - Simple - Thrilling!
Affordable, Handheld, High performance ElectricMagnetic Field Detector!
Free Deluxe carrying case
Mel Meter 8704-R with IR safe Red Backlight Display is Designed Exclusively For Paranormal Investigators
Features:
- Measures EMF, & ambient Temperature
- EMF "Burst" (100msec) mode feature for rapid EMF fluctuation
- EMF Min/Max capture
- Rapid response ambient temperature measurement
- Temperature min/max capture
- Red night view Backlight Display with On/Off Button
- High intensity Red Flashlight
- Includes: (1) 9Vdc Alkaline battery
- Includes: (1) Deluxe carrying case
Specifications:
- LCD Display: 48.8mm x 25.3mm
- Circuit: Custom one-chip of microprocessor LSI circuit.
- Measurement: EMF (Electromagnetic field radiation) and Temperature
- EMF Range/Resolution:
- Micro-Tesla:
- 20 micro Tesla x 0.01 micro Tesla
- 200 micro Tesla x 0.1 micro Tesla
- 2,000 micro Tesla x 1 micro Tesla
- Milli-Gauss(mG):
- 200 mG x 0.1 mG
- 2,000 mG x 1 mG
- 20,000 mG x 10 mG
- 1 micro Tesla = 10 milli-Gauss
- Temperature Range/Resolution:
- -200.0°C to 1370°C x 0.1°C
- -328°F to 2498°F x 0.1°F
- *Type K thermometer (probe not included)
- Range/Resolution/Accuracy
- -50.0 to 1370.0°C x 0.1°C ; ±(0.4% + 0.8°C)
- -50.1 to -199.9°C x 0.1°C ; ±(0.4% + 1°C)
- -58.0 to 2498.0°F x 0.1°F ; ±(0.4% + 1.5°F)
- -58.1 to -327.8°F x 0.1°F ; ±(0.4% + 1.8°F)
- EMF Bandwidth: 30 Hz to 300 Hz
- Axes no. of EMF: Single axis
- Temperature Compensation: Built automatic temp. cold juction compensation circuit for the type K thermometer
- Linear Compensation: Type K thermometer built the linear compensation circuit.
- Offset Adjustment: Available for Temp. function to adjust the zero drift value, adjustment by pushing button.
- Temperatue Probe Inpit Socket: Standard 2 pin thermocouple socket.
- Over-input: Disply shows '----'
- Sampling Time: Approx. 1 second.
- Battery: DC 9V battery
- Power Current: Approx. DC 5 mA with back light off
- Operating Temperature: 0 to 50°C
- Operating Humidity: Less than 80% RH
- Dimension: 152 x 69 x 36.3mm (6.0 x 2.7 x 1.4 inch)
- Weight: 250g / 0.55 lbs
- Accessories inclused: Operation Manual, Soft carrying case(CA-52A)
*Accuracy value is specified for meter only. Type K sensor probe TP-1, TP-02A, TP-03, TP-04 is the optional accessory.
~~~ 01 Year Manufacturer Warranty ~~~
Mel-8704R AC/DC EMF, Temperature, & Flashlight in One Handheld instrument
Professional Instructment for Ghost Detection-Paranormal Activity
Fun - Simple - Thrilling!
Affordable, Handheld, High performance ElectricMagnetic Field Detector!
Free Deluxe carrying case
Mel Meter 8704-R with IR safe Red Backlight Display is Designed Exclusively For Paranormal Investigators
Features:
- Measures EMF, & ambient Temperature
- EMF "Burst" (100msec) mode feature for rapid EMF fluctuation
- EMF Min/Max capture
- Rapid response ambient temperature measurement
- Temperature min/max capture
- Red night view Backlight Display with On/Off Button
- High intensity Red Flashlight
- Includes: (1) 9Vdc Alkaline battery
- Includes: (1) Deluxe carrying case
Specifications:
- LCD Display: 48.8mm x 25.3mm
- Circuit: Custom one-chip of microprocessor LSI circuit.
- Measurement: EMF (Electromagnetic field radiation) and Temperature
- EMF Range/Resolution:
- Micro-Tesla:
- 20 micro Tesla x 0.01 micro Tesla
- 200 micro Tesla x 0.1 micro Tesla
- 2,000 micro Tesla x 1 micro Tesla
- Milli-Gauss(mG):
- 200 mG x 0.1 mG
- 2,000 mG x 1 mG
- 20,000 mG x 10 mG
- 1 micro Tesla = 10 milli-Gauss
- Temperature Range/Resolution:
- -200.0°C to 1370°C x 0.1°C
- -328°F to 2498°F x 0.1°F
- *Type K thermometer (probe not included)
- Range/Resolution/Accuracy
- -50.0 to 1370.0°C x 0.1°C ; ±(0.4% + 0.8°C)
- -50.1 to -199.9°C x 0.1°C ; ±(0.4% + 1°C)
- -58.0 to 2498.0°F x 0.1°F ; ±(0.4% + 1.5°F)
- -58.1 to -327.8°F x 0.1°F ; ±(0.4% + 1.8°F)
- EMF Bandwidth: 30 Hz to 300 Hz
- Axes no. of EMF: Single axis
- Temperature Compensation: Built automatic temp. cold juction compensation circuit for the type K thermometer
- Linear Compensation: Type K thermometer built the linear compensation circuit.
- Offset Adjustment: Available for Temp. function to adjust the zero drift value, adjustment by pushing button.
- Temperatue Probe Inpit Socket: Standard 2 pin thermocouple socket.
- Over-input: Disply shows '----'
- Sampling Time: Approx. 1 second.
- Battery: DC 9V battery
- Power Current: Approx. DC 5 mA with back light off
- Operating Temperature: 0 to 50°C
- Operating Humidity: Less than 80% RH
- Dimension: 152 x 69 x 36.3mm (6.0 x 2.7 x 1.4 inch)
- Weight: 250g / 0.55 lbs
- Accessories inclused: Operation Manual, Soft carrying case(CA-52A)
*Accuracy value is specified for meter only. Type K sensor probe TP-1, TP-02A, TP-03, TP-04 is the optional accessory.
~~~ 01 Year Manufacturer Warranty ~~~