Carbon Monoxide Transmitter/Controller/Alarm with OLED, Output: 4-20mA
with CO and Temperature measurment
(Model No.: TSP-CO-D110-T)
Product Features
- Real-time monitoring Carbon Monoxide concentration in the air and Temperature detection
- Industrial class housings structure design, firm and durable
- Inside famous Japanese Carbon Monoxide sensor with more than 5 years lifetime
- LCD display measured value or setting value
- Double color working and alarm indicator lights, buzzer alarm
- Provide different CO ranges selection
- Provide one on/off relay outputs, a variety of combination to control carbon monoxide and temperature output
- Provide different standard audible alarm with Chinese (GB15322), European (EN50291) and American (UL2034)
- 4-20mA analog linear output for CO measured value
- BACnet -MS/TP or Modbus RTU communication (Optional)
Typical Application
- Underground car parking
- In BMS systems to detect the CO level and the data transmittance
- Public places monitoring and warning
- All ventilation control system
Sensor Specification:
- CO Sensor: Japanese Electrochemical CO Sensor
- Measurement Range: 0 ~ 100ppm
- Accuracy: <±1ppm ( 15~22℃ / 30 ~ 60%RH)
- Stability: ±5% (over 900 days)
- Sensor Lifetime: Up to 3~5 years and replaceable
- Warm Up Time: 60 minutes(Frist use), 1 mniute(daily use)
- Response Time: <130 seconds
- The sensor coverage up to 30 meters radius subject to air movement
- Temperature Range: -20℃ to 60℃
- Temperature Accuracy: ±0.5℃ (20~40℃)
- Display Resolution: 0.1℃
- Temperature Stability: ±0.1℃/year
General Parameters:
- Power supply: 24VAC/24VDC
- Consumption: 2.8W
- Connection Standard: wire cross-section area < 1.5mm2
- Operation Environment: -10℃~50℃; 10~95%RH
- Storage Environment: -10℃~60℃; 0~90%RH, non-condensing
- Dimension: 95mm(W)*117mm(L)*36mm(H)
- Net weight: 280g
- Manufacturing Standard: ISO 9001
- Housings and IP class: PC/ABS fire-proof material; IP30 protection class
- Design Standard: CE-EMC Approval
Outputs:
- LCD Display: OLED screen, display real-time measured values with CO & Temp
- CO analog linear output: 4-20mA
- Relay Dry Contact outputs: one on/off relay outputs, max current 5A (230VAC/30VDC), Resistive load separately controls CO and Temperature
- Double-color working indicator lights: Green: Normal Work; Red: Alarm Indication
- Buzzer Alarm: When CO concentration exceeds the alarm value, the buzzer will ring
Calibration Functions: (Follow-up Supply)
- DIP Switches: Used for zero calibration mode setting
- Sensor air chamber Accessories: Connect windpipe, cover the air chamber to make zero calibration (Opitional)
Accessories
- Cardon Monoixide Controller (Model No. TSP-CO-D110-T)
- User Manual