iAeris 3
OUTDOOR AIR QUALITY MONITOR
(Model No.: iAeris 3X)
~ Guardians of Healthy Outdoors ~
~~ Real-time Air Quality Mastery ~~
Made in Taiwan
Descriptions
The Aeris3 outdoor air quality detector is designed to measure and monitor various air pollutants and meteorological parameters in outdoor environments.
- Particulate Matter Monitoring: Measures concentrations of PM2.5 and PM10, crucial particles linked to air quality and health.
- Gas Detection: Monitors concentrations of gases such as carbon monoxide (CO), ozone (O3), nitrogen dioxide (NO2), sulfur dioxide (SO2), common air pollutants.
- Temperature and Humidity Measurement: Measures temperature and humidity, vital parameters for understanding air quality and human comfort.
- TVOC Detection: Monitors TVOC concentration from various sources, including industrial, traffic, and building materials.
- Data Transmission: Capable of transmitting collected data to a central monitoring system for real-time monitoring and analysis.
Applicable in environmental monitoring, health research, urban governance, and air quality management.
Product Features
- With professional airflow design.
- Sensor module features proprietary algorithms and independent calibration for reliable accuracy.
- Multiple communication interfaces, including RS485, optional WiFi, NB- IoT, and 4G, meeting diverse needs.
- Supports various transmission modes like Modbus-RTU, Modbus-TCP, HTTP, MQTT, etc.
- Built-in memory for real-time data storage, optional cloud platform for easy management and analysis.
- Modular sensor design, with independent modules for diverse air factor detection needs.
- Certified by the Environmental Protection Administration for PM2.5 standards, quality assured by the ITRI.
Applications
- Outdoor
- Schoole
- Internet of Things
- Smart Street Lighting
- Smart City
Sensors Specifications:
- Temperature
- Range: -40℃~125℃
- Resolution: 0.1℃
- Accuracy*: ±0.5℃
- Detection Method: MEMS
- Response time: 30sec
- Warmup time: 60sec
- Relative Humidity
- Range: 0~100%RH
- Resolution: 0.1%
- Accuracy*: ±5% RH
- Detection Method: MEMS
- Response time: 30sec
- Warmup time: 60sec
- Carbon Dioxide (CO2)
- Range: 0 ~ 5,000ppm
- Resolution: 1 ppm
- Accuracy*: ±30ppm±3% of reading
- Detection Method: NDIR
- Response time: 120sec
- Warmup time: 60sec
- Carbon Monoxide (CO)
- Range: 0 ~ 1,000ppm
- Resolution: 1 ppm
- Accuracy*: ±5ppm±5% of reading
- Detection Method: Electrochemistry
- Response time: 60sec
- Warmup time: 60sec
- Dust (PM2.5)
- Range: 1 to 1000μg/m3
- Resolution: 1 μg/m3
- Accuracy*: ±10ug/m3±10% of reading
- Detection Method: Optical
- Response time: 10sec
- Warmup time: 300sec
- Dust (PM10)
- Range: 1 to 1000μg/m3
- Resolution: 1 μg/m3
- Accuracy*: ±10ug/m3±10% of reading
- Detection Method: Optical
- Response time: 10sec
- Warmup time: 300sec
- Airbone Chemicals (TVOCs)
- Range: 0 ~ 60 ppm
- Resolution: 0.01 ppm
- Accuracy*: ±0.1ppm±10% of reading
- Detection Method: MEMS
- Response time: 10sec
- Warmup time: 300sec
- Formaldehyde (HCHO)
- Range: 0.01 ~ 5ppm
- Resolution: 0.01 ppm
- Accuracy*: ±0.02ppm±10% of reading
- Detection Method: Electrochemical
- Response time: 30sec
- Warmup time: 300sec
- Ozone (O3)
- Range: 0 ~ 5ppm
- Resolution: 0.01 ppm
- Accuracy*: ±0.1ppm±10% of reading
- Detection Method: Electrochemical
- Response time: 60sec
- Warmup time: 600sec
- Nitrogen Dioxide (NO2)
- Range: 0 ~ 20ppm
- Resolution: 0.01 ppm
- Accuracy*: ±2% of FS
- Detection Method: Electrochemical
- Response time: 60sec
- Warmup time: 600sec
- Ammonia (NH3)
- Range: 0 ~ 100ppm
- Resolution: 0.01 ppm
- Accuracy*: ±2% of FS
- Detection Method: Electrochemical
- Response time: 60sec
- Warmup time: 600sec
- Sulfur Dioxide (SO2)
- Range: 0 ~ 20ppm
- Resolution: 0.01 ppm
- Accuracy*: ±2% of FS
- Detection Method: Electrochemical
- Response time: 60sec
- Warmup time: 600sec
- Hydrogen Sulfide (N2S)
- Range: 0 ~ 100ppm
- Resolution: 0.01 ppm
- Accuracy*: ±2% of FS
- Detection Method: Electrochemical
- Response time: 60sec
- Warmup time: 600sec
* Testing conditions at 25℃ environment
System Specifications:
- Operating Environment: -10°C to 50°C, below 90% RH
- Storage Temperature: -20°C to 70°C, below 90% RH
- Communication Protocol: Modbus -RTU, Modbus-TCP/HTTP/MQTT
- Transmission Interface: Support NB-IoT / 4G / WiFi / RS485
- Power Supply: Optional AC 110~240V/DC 12~24V/DC 5V (optional)
- Power Consumption: 4W max. (excluding charging module)
- Dimensions: 180mm (L) x 265mm (W) x 138mm (H)
- Weight: 945g max. (excluding charging module)
Model
Model |
T/RH/PM2.5 |
PM10 |
CO |
O3 |
TVOC |
NO2 |
SO2 |
CO2(*) |
NH3/H2S(*) |
iAeris31 |
V |
|
|
|
|
|
|
|
|
iAeris32 |
V |
|
|
|
V |
|
|
|
|
iAeris33 |
V |
V |
V |
V |
V |
|
|
|
|
iAeris35 |
V |
V |
V |
V |
V |
V |
V |
|
|
(*)Sensor factors can also be customarily combined based on customer requirements
iAeris 3
OUTDOOR AIR QUALITY MONITOR
(Model No.: iAeris 3X)
~ Guardians of Healthy Outdoors ~
~~ Real-time Air Quality Mastery ~~
Made in Taiwan
Descriptions
The Aeris3 outdoor air quality detector is designed to measure and monitor various air pollutants and meteorological parameters in outdoor environments.
- Particulate Matter Monitoring: Measures concentrations of PM2.5 and PM10, crucial particles linked to air quality and health.
- Gas Detection: Monitors concentrations of gases such as carbon monoxide (CO), ozone (O3), nitrogen dioxide (NO2), sulfur dioxide (SO2), common air pollutants.
- Temperature and Humidity Measurement: Measures temperature and humidity, vital parameters for understanding air quality and human comfort.
- TVOC Detection: Monitors TVOC concentration from various sources, including industrial, traffic, and building materials.
- Data Transmission: Capable of transmitting collected data to a central monitoring system for real-time monitoring and analysis.
Applicable in environmental monitoring, health research, urban governance, and air quality management.
Product Features
- With professional airflow design.
- Sensor module features proprietary algorithms and independent calibration for reliable accuracy.
- Multiple communication interfaces, including RS485, optional WiFi, NB- IoT, and 4G, meeting diverse needs.
- Supports various transmission modes like Modbus-RTU, Modbus-TCP, HTTP, MQTT, etc.
- Built-in memory for real-time data storage, optional cloud platform for easy management and analysis.
- Modular sensor design, with independent modules for diverse air factor detection needs.
- Certified by the Environmental Protection Administration for PM2.5 standards, quality assured by the ITRI.
Applications
- Outdoor
- Schoole
- Internet of Things
- Smart Street Lighting
- Smart City
Sensors Specifications:
- Temperature
- Range: -40℃~125℃
- Resolution: 0.1℃
- Accuracy*: ±0.5℃
- Detection Method: MEMS
- Response time: 30sec
- Warmup time: 60sec
- Relative Humidity
- Range: 0~100%RH
- Resolution: 0.1%
- Accuracy*: ±5% RH
- Detection Method: MEMS
- Response time: 30sec
- Warmup time: 60sec
- Carbon Dioxide (CO2)
- Range: 0 ~ 5,000ppm
- Resolution: 1 ppm
- Accuracy*: ±30ppm±3% of reading
- Detection Method: NDIR
- Response time: 120sec
- Warmup time: 60sec
- Carbon Monoxide (CO)
- Range: 0 ~ 1,000ppm
- Resolution: 1 ppm
- Accuracy*: ±5ppm±5% of reading
- Detection Method: Electrochemistry
- Response time: 60sec
- Warmup time: 60sec
- Dust (PM2.5)
- Range: 1 to 1000μg/m3
- Resolution: 1 μg/m3
- Accuracy*: ±10ug/m3±10% of reading
- Detection Method: Optical
- Response time: 10sec
- Warmup time: 300sec
- Dust (PM10)
- Range: 1 to 1000μg/m3
- Resolution: 1 μg/m3
- Accuracy*: ±10ug/m3±10% of reading
- Detection Method: Optical
- Response time: 10sec
- Warmup time: 300sec
- Airbone Chemicals (TVOCs)
- Range: 0 ~ 60 ppm
- Resolution: 0.01 ppm
- Accuracy*: ±0.1ppm±10% of reading
- Detection Method: MEMS
- Response time: 10sec
- Warmup time: 300sec
- Formaldehyde (HCHO)
- Range: 0.01 ~ 5ppm
- Resolution: 0.01 ppm
- Accuracy*: ±0.02ppm±10% of reading
- Detection Method: Electrochemical
- Response time: 30sec
- Warmup time: 300sec
- Ozone (O3)
- Range: 0 ~ 5ppm
- Resolution: 0.01 ppm
- Accuracy*: ±0.1ppm±10% of reading
- Detection Method: Electrochemical
- Response time: 60sec
- Warmup time: 600sec
- Nitrogen Dioxide (NO2)
- Range: 0 ~ 20ppm
- Resolution: 0.01 ppm
- Accuracy*: ±2% of FS
- Detection Method: Electrochemical
- Response time: 60sec
- Warmup time: 600sec
- Ammonia (NH3)
- Range: 0 ~ 100ppm
- Resolution: 0.01 ppm
- Accuracy*: ±2% of FS
- Detection Method: Electrochemical
- Response time: 60sec
- Warmup time: 600sec
- Sulfur Dioxide (SO2)
- Range: 0 ~ 20ppm
- Resolution: 0.01 ppm
- Accuracy*: ±2% of FS
- Detection Method: Electrochemical
- Response time: 60sec
- Warmup time: 600sec
- Hydrogen Sulfide (N2S)
- Range: 0 ~ 100ppm
- Resolution: 0.01 ppm
- Accuracy*: ±2% of FS
- Detection Method: Electrochemical
- Response time: 60sec
- Warmup time: 600sec
* Testing conditions at 25℃ environment
System Specifications:
- Operating Environment: -10°C to 50°C, below 90% RH
- Storage Temperature: -20°C to 70°C, below 90% RH
- Communication Protocol: Modbus -RTU, Modbus-TCP/HTTP/MQTT
- Transmission Interface: Support NB-IoT / 4G / WiFi / RS485
- Power Supply: Optional AC 110~240V/DC 12~24V/DC 5V (optional)
- Power Consumption: 4W max. (excluding charging module)
- Dimensions: 180mm (L) x 265mm (W) x 138mm (H)
- Weight: 945g max. (excluding charging module)
Model
Model |
T/RH/PM2.5 |
PM10 |
CO |
O3 |
TVOC |
NO2 |
SO2 |
CO2(*) |
NH3/H2S(*) |
iAeris31 |
V |
|
|
|
|
|
|
|
|
iAeris32 |
V |
|
|
|
V |
|
|
|
|
iAeris33 |
V |
V |
V |
V |
V |
|
|
|
|
iAeris35 |
V |
V |
V |
V |
V |
V |
V |
|
|
(*)Sensor factors can also be customarily combined based on customer requirements