CEM DT-9881M
5-in-1 Air Particle Counter
with TFT color LCD display & Camera function
Particle Counter, Temperature and Humidity Measurement
and Gas (HCHO, CO) Detectors
CEM DT-9881M Air Particle Counter + Gas Detector provides fast,easy and accurate readings for particle count, It can measure Mass Concentration, GAS Formaldehyde (HCHO) & Carbon Monoxide (CO) detectection, air temperature & relative humidity &,most surface temperature measurements.
The CEM DT-9881M Air Particle Counter has many functions. With it is possible to determine the number of particles in the size of 0.3, 2.5 and 10 µm. In addition to measuring the particles, the fine dust it can also measure the PM 2.5 and PM 10 mass concentration. The mass concentration of the fine dust determines the weight of the particles in one cubic metre.
In addition the CEM DT-9881M can also determine the formaldehyde content in ppm. During this HCHO measurement, the temperature, the ambient humidity and the dew point are determined and displayed by it. As a further important feature it can all store data and it is therefore possible to evaluate all measured values after a measurement.
It is the ideal instrument for environmental safety and energy saving surveys.
Features
- Measures suspended particle concentration in the air of the weight method (PM2.5/PM10)
- 2.8" TFT 320x240 pixels Color LCD display
- Images(JPEG) & Video(3GP)
- Simultaneously measure and display 6 channel of particle sizes, measure particle size down to 0.3 μm
- IR temperature measure & Laser targeting
- GAS (HCHO, CO) detectors
- Air temperature and humidity, Dew point & Wet bulb temperature
- Max, Min, DIF, AVG record, Date/time setup controls, High and low alarm
- Adjustable emissivity & Trigger lock
- MicroSD (MAX. use 8GB) memory card, USB interface
- Auto Power Off
- Selectable sample time, count data, programmable delay
- Store 5000 records of date, time, counts, relative humidity, temperature, sample volumes, alarms and location label
- Language selection English, Chinese, French, German, Spaish
Specifications:
- Particle Counter
- Channel: 0.3, 0.5, 1.0, 2.5, 5.0, 10μm
- Flow Rate: 0.1ft3(2.83L/min) controlled by internal pump
- Count Modes: Totalize, Differential, Concentration
- Mass Concentration Channel:
- PM2.5 :0~500ug/m³
- PM10:0~500ug/m³
- Coincidence Loss: 5% at 2,000,000 particles per ft³
- Air Temperature Measure
- Air Temp Range: 0 to 50ºC/32 to 122ºF; Basic Accuracy: ±0.5ºC/1ºF
- Humidity Range: 0 to 100%RH; Basic Accuracy: ±2.5%RH(20%~80%RH)
- Dew Point Temp. Range: -30~100ºC/ -22~199ºF
- Wet Bulb Temp. Range: 0~80ºC/ 32~176ºF
- GAS Detectors
- HCHO (methanal)
Range: 0.01~5.00ppm
Basic Accuracy: ±5%± 0.01ppm
- CO (carbon monoxide)
Range: 0~1000ppm
Basic Accuracy:±5% ± 10ppm
Standard:
- ASTM F649-01
- ASTM F328-98
- EN 61326
- JIS B9921
- GB 16292
Package includes:
- Particle Counter
- User Manual
- USB Cable
- Zero Count Filter
- 7.4 Li-ion Battery
- AC Adapter
- Tripod
- Carrying case
- Manufacturer's Calibration Test Report
CEM DT-9881M
5-in-1 Air Particle Counter
with TFT color LCD display & Camera function
Particle Counter, Temperature and Humidity Measurement
and Gas (HCHO, CO) Detectors
CEM DT-9881M Air Particle Counter + Gas Detector provides fast,easy and accurate readings for particle count, It can measure Mass Concentration, GAS Formaldehyde (HCHO) & Carbon Monoxide (CO) detectection, air temperature & relative humidity &,most surface temperature measurements.
The CEM DT-9881M Air Particle Counter has many functions. With it is possible to determine the number of particles in the size of 0.3, 2.5 and 10 µm. In addition to measuring the particles, the fine dust it can also measure the PM 2.5 and PM 10 mass concentration. The mass concentration of the fine dust determines the weight of the particles in one cubic metre.
In addition the CEM DT-9881M can also determine the formaldehyde content in ppm. During this HCHO measurement, the temperature, the ambient humidity and the dew point are determined and displayed by it. As a further important feature it can all store data and it is therefore possible to evaluate all measured values after a measurement.
It is the ideal instrument for environmental safety and energy saving surveys.
Features
- Measures suspended particle concentration in the air of the weight method (PM2.5/PM10)
- 2.8" TFT 320x240 pixels Color LCD display
- Images(JPEG) & Video(3GP)
- Simultaneously measure and display 6 channel of particle sizes, measure particle size down to 0.3 μm
- IR temperature measure & Laser targeting
- GAS (HCHO, CO) detectors
- Air temperature and humidity, Dew point & Wet bulb temperature
- Max, Min, DIF, AVG record, Date/time setup controls, High and low alarm
- Adjustable emissivity & Trigger lock
- MicroSD (MAX. use 8GB) memory card, USB interface
- Auto Power Off
- Selectable sample time, count data, programmable delay
- Store 5000 records of date, time, counts, relative humidity, temperature, sample volumes, alarms and location label
- Language selection English, Chinese, French, German, Spaish
Specifications:
- Particle Counter
- Channel: 0.3, 0.5, 1.0, 2.5, 5.0, 10μm
- Flow Rate: 0.1ft3(2.83L/min) controlled by internal pump
- Count Modes: Totalize, Differential, Concentration
- Mass Concentration Channel:
- PM2.5 :0~500ug/m³
- PM10:0~500ug/m³
- Coincidence Loss: 5% at 2,000,000 particles per ft³
- Air Temperature Measure
- Air Temp Range: 0 to 50ºC/32 to 122ºF; Basic Accuracy: ±0.5ºC/1ºF
- Humidity Range: 0 to 100%RH; Basic Accuracy: ±2.5%RH(20%~80%RH)
- Dew Point Temp. Range: -30~100ºC/ -22~199ºF
- Wet Bulb Temp. Range: 0~80ºC/ 32~176ºF
- GAS Detectors
- HCHO (methanal)
Range: 0.01~5.00ppm
Basic Accuracy: ±5%± 0.01ppm
- CO (carbon monoxide)
Range: 0~1000ppm
Basic Accuracy:±5% ± 10ppm
Standard:
- ASTM F649-01
- ASTM F328-98
- EN 61326
- JIS B9921
- GB 16292
Package includes:
- Particle Counter
- User Manual
- USB Cable
- Zero Count Filter
- 7.4 Li-ion Battery
- AC Adapter
- Tripod
- Carrying case
- Manufacturer's Calibration Test Report