LUX Light Meter
Luminance and Luminous Intensity Measurement
(Model No.: TM- 215)
Quality Product ~ Made in Taiwan
Application:
Lux Light Meter is designed for measuring Luminance (unit: Lux/FC) and Luminous intensity (unit: candela or CD), while complying with the specifications: DIN5032-7-2017 Class C, JJG 245-2005 Class B, JIS C 1609-1: 2006 Class A, CNS5119.
Features:
-
Display of reading: LCD display with 4 digits, where the maximum number shown is 9999.
-
Unit: LUX /FC/CD
-
Data holding function (HOLD)
-
Automatic and manual shifting
-
Backlight display
-
Auto power off (15 minutes after last usage) and
-
disable the function.
-
Maximum/minimum hold.
-
Overload indication: “OL”.
- Datalogging capacity 7000 records.
-
Interval of data storage: 1 second to 10 days.
-
Low battery indication
-
Average of 4 or 5 point
-
Transmittance measurement
Specifications:
- Measuring range:
- 400.0, 4,000, 40,000, 400,000 Lux
- 40.00, 400.0, 4,000, 40,000 Foot-Candle
- Resolution:
- 0.1, 1, 10, 100 Lux
- 0.01, 0.1, 1, 10 Foot-Candle
- Accuracy: ±3% (for light source A of 2856˚K)
- Relative Spectral Response (f1´): ±8% CIE visible light V(λ)
- Cosine characteristic (f2): ±6%
- Oblique incident light characteristic (angle):
- 10˚: ±1.5%
- 30˚: ±3%
- 60˚: ±10%
- 80˚: ±30%
-
Linearity (JISC 1609-1:2006) (Accuracy of various light sources):
-
Initial Adjustment(fADJ) DIN5032 Part7 JJG 245-2005: ±5% with reading ±1
-
Linearity(f3) DIN5032 Part7 JJG 245-2005: ±2.5%
- Range change(f11): ±2%
- Fatigue(f5): -1%
- IR response(fIR): ±4%
- UV response(fUV): ±2.5%
- Temperature(f6T): ±1%
- Response time:
- Auto shifting: ≦5 seconds
- Manual shifting: ≦2 seconds
Accuracy is specified for ambient temperatures between 15°C to 28°C (59°F to 82°F)
Standards Certification:
- CE
- ROHS
- DIN5032-7-2017 Class C
- JJG 245-2005 Class B
- JIS C 1609-1: 2006 Class A
- CNS5119
Dimension:
Accessories:
LUX Light Meter
Luminance and Luminous Intensity Measurement
(Model No.: TM- 215)
Quality Product ~ Made in Taiwan
Application:
Lux Light Meter is designed for measuring Luminance (unit: Lux/FC) and Luminous intensity (unit: candela or CD), while complying with the specifications: DIN5032-7-2017 Class C, JJG 245-2005 Class B, JIS C 1609-1: 2006 Class A, CNS5119.
Features:
-
Display of reading: LCD display with 4 digits, where the maximum number shown is 9999.
-
Unit: LUX /FC/CD
-
Data holding function (HOLD)
-
Automatic and manual shifting
-
Backlight display
-
Auto power off (15 minutes after last usage) and
-
disable the function.
-
Maximum/minimum hold.
-
Overload indication: “OL”.
- Datalogging capacity 7000 records.
-
Interval of data storage: 1 second to 10 days.
-
Low battery indication
-
Average of 4 or 5 point
-
Transmittance measurement
Specifications:
- Measuring range:
- 400.0, 4,000, 40,000, 400,000 Lux
- 40.00, 400.0, 4,000, 40,000 Foot-Candle
- Resolution:
- 0.1, 1, 10, 100 Lux
- 0.01, 0.1, 1, 10 Foot-Candle
- Accuracy: ±3% (for light source A of 2856˚K)
- Relative Spectral Response (f1´): ±8% CIE visible light V(λ)
- Cosine characteristic (f2): ±6%
- Oblique incident light characteristic (angle):
- 10˚: ±1.5%
- 30˚: ±3%
- 60˚: ±10%
- 80˚: ±30%
-
Linearity (JISC 1609-1:2006) (Accuracy of various light sources):
-
Initial Adjustment(fADJ) DIN5032 Part7 JJG 245-2005: ±5% with reading ±1
-
Linearity(f3) DIN5032 Part7 JJG 245-2005: ±2.5%
- Range change(f11): ±2%
- Fatigue(f5): -1%
- IR response(fIR): ±4%
- UV response(fUV): ±2.5%
- Temperature(f6T): ±1%
- Response time:
- Auto shifting: ≦5 seconds
- Manual shifting: ≦2 seconds
Accuracy is specified for ambient temperatures between 15°C to 28°C (59°F to 82°F)
Standards Certification:
- CE
- ROHS
- DIN5032-7-2017 Class C
- JJG 245-2005 Class B
- JIS C 1609-1: 2006 Class A
- CNS5119
Dimension:
Accessories: